Browsing by Author "Nogueira, Susana"
Now showing 1 - 10 of 12
Results Per Page
Sort Options
- Assessment of Indoor Environmental Quality in Elderly Care CentersPublication . Cano, Manuela; Nogueira, Susana; Alves, Marta; Papoila, Ana Luísa; Aguiar, Fátima; Rosa, Nuno; Brás, Maria Clementina; Quintas, Maria Carmo; Pinhal, Hermínia; Nogueira, Ana; Proença, Carmo; Teixeira, João P.The aim of this study was to characterize indoor environmental quality in a representative sample of Elderly Care Centers (ECC) in order to associate it with ventilation, health and comfort of elderly people. Indoor air quality (IAQ) parameters and thermal comfort were measured twice, during winter and spring/summer seasons, from 18 Elderly Care Centers (ECC) located in Lisbon, with a total of 116 rooms evaluated. Carbon dioxide and carbon monoxide were monitored during occupation periods using the Indoor Air Quality Meter (TSI, model 7545, USA). Formaldehyde was collected by active sampling on impingers, using personal pumps at an airflow of 1L/min and analyzed according to NIOSH 3500 method, using visible spectrometry (UV4, UNICAM). PM10 and PM2,5 were collected by active sampling on pre-weighted PTFE filters mounted on PM10 and PM2,5 collectors (PEM, SKC), using personal pumps operating at 2L/min, followed by gravimetric analysis for particle mass according to the method IP-10A by SKC (2004). Duplicate samples of total volatile organic compounds were collected on TENAX Tubes (Ref. 25054, Supelco) using SKC personal pumps calibrated to 0.05 L/min and analyzed after thermal desorption according to ISO 16000-part 6 using gas chromatography. Duplicate samples of viable airborne bacteria and fungi were collected using the Microbiological Air Sampler (Merck) and TSA, McK and MEA for total bacteria, Gram-negative bacteria and fungi, respectively. Whole-body thermal comfort evaluation was based on PMV (Predicted Mean Vote) and PPD (Predicted Percentage of Dissatisfied) indices, according to the ISO 7730:2005. Considering the obtained results for environmental indoor quality it is possible to conclude that thermal comfort was not reached in more than 30% of the rooms. In winter, carbon dioxide concentrations were above the reference in 20% of the rooms. PM10 and PM2,5 mean concentrations were above the reference levels in approximately 25% and 30% of the rooms, respectively. Microbiological contamination (total bacteria and fungi) was above the reference levels in more than 35% of the rooms. Indoor environmental quality should be improved by controlling contamination sources, ventilation and thermal parameters (or clothing) in order to obtain healthier environments for the elderly.
- Avaliação da qualidade do ar interior em lares de idosos, 2013-2014: projeto GERIAPublication . Cano, Manuela; Nogueira, Susana; Alves, Marta; Papoila, Ana Luísa; Aguiar, Fátima; Rosa, Nuno; Brás, Maria Clementina; Quintas, Maria do Carmo; Pinhal, Hermínia; Nogueira, Ana; Proença, Carmo; Teixeira, João PauloO risco da população idosa desenvolver efeitos adversos em virtude da exposição a contaminantes químicos e microbiológicos do ar interior é mais elevado tanto pelo facto do seu sistema imunitário ser mais débil, como por este grupo etário permanecer no interior de edifícios por períodos mais longos. O objetivo deste estudo foi a caraterização da qualidade do ar interior numa amostra representativa de lares de idosos de modo a estudar a sua relação com a ventilação dos locais e a saúde/qualidade de vida dos utentes. O estudo apresentado incidiu sobre a avaliação da qualidade do ar interior em 18 lares de idosos situados em Lisboa (116 locais avaliados), em duas campanhas, uma no inverno e outra na primavera/verão e incluiu a avaliação de contaminação do ar por agentes químicos - dióxido de carbono (CO2 ), monóxido de carbono (CO), formaldeído (HCHO), compostos orgânicos voláteis totais (COVT), PM10 e PM2,5; por agentes microbiológicos – bactérias e fungos. Os resultados indicam que, de um modo geral a contaminação do ar por compostos orgânicos voláteis totais e formaldeído é baixa. Contudo, os valores de referência são excedidos para o dióxido de carbono, microrganismos e as partículas em 20%, 35% e 25-30% dos locais estudados respetivamente. Assim, há que identificar as fontes de contaminação do ar por partículas por forma e reduzir os efeitos adversos associados à exposição e melhorar a ventilação dos lares, particularmente no inverno, por forma a conseguir ambientes interiores mais saudáveis.
- Avaliação de idosos institucionalizados por espirometria e condensado brônquico do ar exalado: efeitos da exposição ambientalPublication . Belo, Joana; Carreiro-Martins, Pedro; Papoila, Ana Luísa; Palmeiro, Teresa; Caires, Iolanda; Alves, Marta; Nogueira, Susana; Aguiar, Fátima; Mendes, Ana; Cano, Manuela; Botelho, Maria A.; Neuparth, NunoNo estudo geriátrico dos efeitos na saúde da qualidade do ar interior em lares da 3.ª idade de Portugal (GERIA) foi estabelecido como objetivo principal de estudar os efeitos da qualidade do ar interior (IAQ) de equipamentos residenciais para pessoas idosos (ERPI) na saúde respiratória de idosos institucionalizados. Um total de 269 idosos responderam a um questionário elaborado pela equipa de investigadores do projeto GERIA, realizaram uma espirometria e a 150 idosos foi recolhida uma amostra de condensado brônquico exalado (EBC), para análise do respetivo pH e concentração de nitritos. Em relação aos dados sociodemográficos destaca se uma média de idade de 81,9±7,5 anos e uma maioria (70,6%) de idosos do sexo feminino. Relativamente aos resultados da espirometria, observou se que 14,5% apresentaram uma obstrução das vias aéreas. Os valores medianos das concentrações dos poluentes ambientais não revelaram uma concentração acima do referencial de segurança, porém foram observados valores máximos elevados e acima desse referencial. Da análise multivariada verificou se que cada incremento de 100 µg/m3 nos compostos orgânicos voláteis (TVOCS) se encontrava associado positiva mente a possibilidade acrescida dos idosos terem reportado infeção respiratória nos últimos três meses (=1.05; 95% CI: 1.00 to 1.09). Verificou se que o valor do pH diminuía com uma maior exposição a PM2,5 (= 0.04, 95%: 0.06 to 0.01e por cada aumento de 10 µg/m3). No que concerne à exposição a bactérias, verificou se que esta se associava positivamente à possibilidade dos idosos terem uma FVC diminuída (= 0,53, 95%: 0,87 a 0,20) e uma relação FEV1 /FVC aumentada (=0,22, 95%:0,08 a 0,37)
- Caracterização Experimental das Taxas de Renovação Horária em Residências para Pessoas IdosasPublication . Aelenei, Daniel; Nogueira, Susana; Viegas, João; Mendes, Ana; Cano, Manuela; Cerqueira, FábioÉ do conhecimento geral que a qualidade do ar interior influencia a qualidade de vida dos ocupantes dos edifícios e que pode ter implicações significativas no seu estado de saúde. As pessoas idosas constituem um grupo mais vulnerável que pode ser afectado quando exposto a um ambiente interior de menor qualidade. O projecto GERIA reúne uma equipa multidisciplinar que tem como objectivo principal estudar as possíveis associações entre as condições de ventilação existentes em estruturas residenciais para pessoas idosas (ERPI), a qualidade do ar interior (QAI) e a prevalência de doenças do foro respiratório nos residentes. Para alcançar este objectivo o projecto foi es-sencialmente desenvolvido em duas fases. Para avaliar as características construtivas e a saúde e a qualidade de vida dos residentes, na fase I, foi realizado um estudo preliminar em 21 ERPI no Porto e 33 em Lisboa recorrendo a inspecções visuais e questionários. Na fase II, a partir dos 54 considerados na fase I, foram seleccionados através duma análise de clus-ters um número de 4 ERPI no Porto e 18 em Lisboa onde foi avaliada novamente a saúde respiratória dos residentes em conjunto com a QAI e a qualidade da ventilação. O presente artigo pretende apresentar os primeiros resultados de uma campanha experi-mental realizada durante os meses de Fevereiro e Março de 2014 na fase II, com o objectivo de caracterizar as taxas de renovação horária em 15 ERPI, sendo 11 em Lisboa e 4 no Por-to. Na sequência do trabalho realizado, que consistiu em realizar medições com recurso ao método de gás traçador (técnica PFT) ao longo de períodos de tempo de duas semanas, fo-ram determinadas as taxas de renovação horária num número de quartos seleccionados que varia de 2 a 27, conforme a dimensão dos edifícios.
- Environment and Health in Children Day Care CentresPublication . Neuparth, Nuno; Papoila, Ana Luísa; Aelenei, Daniel; Cano, Manuela; Paixão, Paulo; Viegas, João; Martins, Pedro; Araújo Martins, José; Leiria Pinto, Paula; Caires, Iolanda; Pedro, Catarina; Nogueira, Susana; Mendes, Ana; Aguiar, Fátima; Teixeira, João Paulo; Proença, Carmo; Piedade, Cátia; Santos, Madalena; Silvestre, Maria José; Brum, Laura; Nunes, Baltazar; Guiomar, Raquel; Curran, Martin D.; Carvalho, Ana; Marques, Teresa; Virella, Daniel; Alves, Marta; Marques, João; Rosado-Pinto, José; Neuparth, Nuno; Aelenei,Daniel; Caires, Iolanda; Teixeira, João Paulo; Viegas, João; Cano, Manuela; Pinto, Paula LeiriaThis project addresses a set of common clinical problems in the context of children attending day care centres. It is common sense that children get sick more often as soon as they start attending a day care centre on a daily basis and this is particularly true for some groups at risk, as wheezing infants and wheezing pre-school children. Concerning this, some questions remain unclear: 1. The role of indoor air quality - what is the health impact of indoor air environment (including indoor pollutants, house dust mite, temperature and humidity) in wheezing children? 2. The role of virus infections - We don’t know the real role of virus infections in respiratory conditions at day care centre level. There is a lack of information concerning how indoor air environment influence virus infections. 3. The role of building ventilation - what is the impact of building ventilation in the health of wheezing and non-wheezing children? How is ventilation affecting indoor air quality? How is ventilation of day care centres affected by the structure of the buildings? 4. Social impact of this study - what should be the recommendations to improve IAQ? What is new in this project is the collaboration of a health team (medical doctors and other health professionals) with environment specialists, mechanical, civil engineers, epidemiologists and statisticians.
- Estudo da qualidade do ar interior em creches e infantários (projeto ENVIRH)Publication . Viegas, João; Cano, Manuela; Nogueira, Susana; Papoila, Ana LuísaC; Proença, Maria do Carmo; Aelenei, Daniel; Neuparth, NunoEncontra-se em curso um projeto de investigação, co-financiado pela FCT, que tem por objetivo estudar qual o impacte que a qualidade do ar interior tem na prevalência de doenças do foro respiratório em crianças que frequentam creches e infantários em Lisboa e Porto. Este projeto envolve investigadores do LNEC, do INSA Dr. Ricardo Jorge, da Faculdade de Ciências Médicas (UNL) e da Faculdade de Ciências e Tecnologia (UNL). O faseamento deste estudo enquadrou uma primeira fase de análise das condições construtivas dos edifícios, uma medição sumária do teor de CO2 em salas de atividades e um inquérito relativo ao estado de saúde das crianças, em 45 creches e jardins-de-infância de Lisboa (25) e do Porto (20); numa segunda fase incluiu a medição da qualidade do ar interior, da taxa de ventilação e do estado de saúde das crianças num conjunto mais limitado de escolas (10 em Lisboa e 9 no Porto); numa fase final está a ser desenvolvida a simulação da ventilação em duas escolas. Nesta comunicação apresentam-se os resultados obtidos pelo LNEC e pelo INSA Dr. Ricardo Jorge relativos à análise da qualidade do ar e à ventilação. Estes resultados revelam que na generalidade dos locais os caudais de ventilação são muito baixos, sendo a qualidade do ar interior insuficiente face ao RSECE e a valores recomendados pela literatura.
- Factores de Risco para sibilância: resultados da Fase1 do Projecto "Ambiente e Saúde em Creches e Infantários" (ENVIRH)Publication . Martins, Pedro; Papoila, Ana Luísa; Marques, João; Caires, Iolanda; Martins, José; Pedro, Catarina; Manilha, Maria do Carmo; Cano, Manuela; Silva, Ana Sofia; Aelenei, Daniel; Nogueira, Susana; Paixão, João Paulo; Teixeira, João Paulo; Viegas, João; Rosado-Pinto, José; Leiria-Pinto, Paula; Neuparth, NunoMuitas crianças com idade inferior a 6 anos apresentam sibilância no decurso de infecções respiratórias. O projecto ENVIRH tem como parte integrante dos seus objectivos identificar factores de risco para sibilância relacionados com as características construtivas / qualidade do ar interior das creches e infantários. Métodos: No âmbito do Projecto ENVIRH foram seleccionadas aleatoriamente 46 Instituições Particulares de Solidariedade Social (IPSS) das cidades de Lisboa e Porto, estratificadas por freguesia e número de alunos. As escolas seleccionadas corresponderam a metade das IPSS destas duas cidades. Em Outubro de 2010 foi entregue aos pais de todas as crianças uma versão resumida do questionário do estudo ISAAC (n=5161). Efectuou-se no mesmo período uma avaliação sumária das características construtivas e da qualidade do ar de todas as escolas participantes. Para a análise dos dados foram utilizadas Equações de Estimação Generalizadas (GEE), de forma considerar a estrutura de correlação dos indivíduos de cada IPSS. Resultados: Foram devolvidos 3185 questionários. A idade média foi de 3.1 ± 1.5 anos, sendo 50.5% do sexo masculino. A prevalência reportada de sibilância nos 12 meses anteriores foi de 27.5% (IC 95%: 25.9% - 29.0%). Das diversas varáveis consideradas - idade, sexo, escolaridade dos pais, tabagismo passivo, existência de irmãos mais velhos, antecedentes de eczema na criança, antecedentes de asma ou rinite nos pais, idade e área da IPSS, número de alunos, existência de bolores na instituição, temperatura, humidade relativa e concentração de CO2 médias do ar interior durante o período de ocupação - somente persistiram significativas na análise multivariável (p<0.05) a idade (OR: 0.74; IC 95: 0.70 - 0.78; p<0.001), antecedentes de eczema (OR: 1.35; IC 95: 1.14 - 1.60; p<0.001), e antecedentes de asma ou rinite nos pais (OR: 1.99; IC 95: 1.67 - 2.38; p<0.001). Um aumento médio de 100 ppm de CO2 também se associou com sibilância nos 12 meses anteriores (OR: 1.02; IC 95: 1.01 - 1.03; p=0.008). Conclusão: Tratando-se a concentração de CO2 um marcador indirecto da ventilação e da qualidade do ar interior, os resultados alcançados sugerem a necessidade de introduzir melhorias nestes parâmetros, ao nível das creches e infantários, dado existir uma associação muito significativa das concentrações de CO2 com sibilância.
- Indoor Air Quality in Portuguese Day Care Centers - ENVIRH ProjectPublication . Cano, Manuela; Nogueira, Susana; Papoila, Ana Luísa; Aguiar, Fátima; Martins, Pedro; Marques, João; Caires, Iolanda; Martins, José; Pedro, Catarina; Paixão, Paulo; Rosado-Pinto, José; Leiria-Pinto, Paula; Aelenei, Daniel; Mendes, Ana; Teixeira, João Paulo; Proença, Carmo; Neuparth, NunoThis paper describes field measurements of indoor air quality (IAQ) parameters, performed in 19 Portuguese Children Day Care Centers (CDCC) during the springtime of 2011 and aims to characterize the indoor environment. The results demonstrate an association between carbon dioxide and bacterial concentrations, which in turn are affected by the number of children present in each classroom. Indoor PM10 concentrations were higher than outdoor levels (I/O ratio>1) and was also found statistically significant association between PM10 concentrations and the type of floor covering materials. These results provide evidence that IAQ is inadequate and, as a consequence, human source contaminants such as bacteria and carbon dioxide accumulate indoors. This study suggests that it is necessary to improve ventilation in order to achieve a healthier indoor environment.
- Indoor microbiological contamination in children day care centres – the ENVIRH studyPublication . Cano, Manuela; Nogueira, Susana; Papoila, Ana Luísa; Aguiar, Fátima; Rosa, Nuno; Mendes, Ana; Teixeira, João Paulo; Proença, Carmo; Neuparth, NunoIn developed countries, after their homes, the children day care center (CDCC) is the place where children spend most of their time, so it is important to understand how environmental factors influence children respiratory health. The aim of ENVIRH (Environment and Health in children day care centres) study is to gather information on indoor environment in CDCC in order to correlate it with both ventilation and children’s health. This paper presents field measurements of indoor microbiological parameters, performed in 19 CDCC during spring and winter and aims to characterize the indoor environment. Bacteria and fungi were collected using a MAS-100 impactor with Trypticase Soy Agar, MacConkey Agar and Malt Extract Agar as culture media for total bacteria, Gram-negative bacteria and fungi, respectively. Concentrations were calculated and fungi were identified. Dust samples were collected on filters using a vacuum cleaner with a DustreamTM collector. Concentration of Der p1 and Der f1 dust mite allergens were assayed separately by ELISA quantitative kit. Most of the CDCC revealed bacterial levels above the reference levels defined by the Portuguese legislation. Nurseries presented lower bacterial concentrations than activity rooms. Indoor fungal concentrations were above outdoor levels in 50% of the studied rooms and the predominant mould genera detected in both seasons were Penicillium and Cladosporium. In spring were obtained higher concentrations of house dust mites in dust with 16% of the rooms surpassing the sensitization threshold.
- Numerical evaluation of ventilation performance in children day care centresPublication . Viegas, João Carlos; Nogueira, Susana; Aelenei, Daniel; Cruz, Hildebrando; Cano, Manuela; Neuparth, NunoModelling of ventilation is strongly dependent on the physical characteristics of the building of which precise evaluation is a complex and time consuming task. In the frame of a research project, two children day care centres (CDCC) have been selected in order to measure the envelope air permeability, the flow rate of mechanical ventilation systems and indoor and outdoor temperature. The data obtained was used as input to the computer code CONTAM for ventilation simulations. The results obtained were compared with direct measurements of ventilation flow from short term measurements with CO2 tracer gas and medium term measurements with perfluorocarbon tracer (PFT) gas decay method. After validation, in order to analyse the main parameters that affect ventilation, the model was used to predict the ventilation rates for a wide range of conditions. The purpose of this assessment was to find the best practices to improve natural ventilation. A simple analytical method to predict the ventilation flow rate of rooms is also presented. The method is based on the estimation of wind effect on the room through the evaluation of an average factor ( ) ¥ 2 ΔP / ρ * and on the assessment of relevant cross section of gaps and openings combined in series or in parallel. It is shown that it may be applied with acceptable accuracy for this type of buildings when ventilation is due essentially to wind action.