Estudo para a determinação dos valores de referência das enzimas aspartato aminnotransferase (AST), alanina aminotransferase (ALT) e gama- glutamil transferase (GGT), no soro

dc.contributor.authorAlvim, Marta
dc.contributor.authorAlves, Ana Catarina
dc.contributor.authorVaz, Margarida
dc.contributor.authorAlmeida, Suza
dc.contributor.authorConstantino, José Vicente
dc.contributor.authorBourbon, Mafalda
dc.date.accessioned2022-05-27T16:11:01Z
dc.date.available2022-05-27T16:11:01Z
dc.date.issued2022-05
dc.description.abstractÉ recomendável que cada laboratório se baseie em protocolos e procedimentos operacionais comuns com a finalidade de obter valores de referência “comuns” e “harmonizados” a nível nacional. O objetivo deste trabalho foi determinar os valores de referência das enzimas AST, ALT e GGT. A metodologia teve como base o documento CSLI / IFCC, C28-A3. A amostra inicial foi de 1688 indivíduos de Portugal continental, dos quais 1122 foram excluídos após a análise dos questionários (com patologias e/ou fumadores) de modo a obtermos uma população considerada “saudável”. Após a quantificação das enzimas por um método enzimático, verificou-se que não houve relevância nos resultados para diferentes grupos etários, embora tenha sido observada diferença estatística significativa quanto ao género ( p<0,001). Desta forma, foram calculados os valores de referência para o género feminino e masculino respetivamente da ALT = 7-38U/L e 10-70U/L, da AST = 11-30U/L e 13-53U/L e da GGT = 5-36U/L e 7-80U/L, através do programa IBM SPSS Statistics versão 25. Os valores de referência, no caso do género feminino, foram muito semelhantes aos descritos nos folhetos informativos, enquanto no género masculino verificaram-se valores superiores.pt_PT
dc.description.abstractIt is recommended that each laboratory base itself on common protocols and operating procedures in order to achieve “standard” reference values at national level. The aim of this work is to determine the reference values of the enzymes AST, ALT and GGT. The methodology used was based on the document CSLI / IFCC, C28-A3. From the initial sample of 1688 individuals from mainland Portugal, 1122 were excluded due to the analysis of the questionnaires, (whith pathologies and/or smokers) to obtein a population considered healthy We studied 566 serum samples and quantification of enzymes by an enzymatic method in Cobas INTEGRA 400 Plus, showed no significance diferences in the results for several age groups, although a statistically significant difference was observed regarding gender (p<0,001). Therefore, the reference values for females and males respectively were calculated for ALT = 7-38U/L and 10-70U/L, for AST = 11-30U/L and 13-53U/L and for GGT = 5- 36U/L and 7-80U/L, through the IBM SPSS Statistics version 25 program. The reference values, for females, were very similar to those described by other publications, while for males, higher values were found.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationBoletim Epidemiológico Observações. 2022 janeiro-abril;11(31):44-48pt_PT
dc.identifier.issn0874-2928
dc.identifier.issn2182-8873 (em linha)
dc.identifier.urihttp://hdl.handle.net/10400.18/8029
dc.language.isoporpt_PT
dc.publisherInstituto Nacional de Saúde Doutor Ricardo Jorge, IPpt_PT
dc.subjectAspartato Aminnotransferasept_PT
dc.subjectAlanina Aminotransferasept_PT
dc.subjectGama- glutamil Transferasept_PT
dc.subjectEnzimaspt_PT
dc.subjectValores de Referênciapt_PT
dc.subjectAnálises laboratoriaispt_PT
dc.subjectDoenças Hepatobiliarespt_PT
dc.subjectPortugalpt_PT
dc.titleEstudo para a determinação dos valores de referência das enzimas aspartato aminnotransferase (AST), alanina aminotransferase (ALT) e gama- glutamil transferase (GGT), no soropt_PT
dc.title.alternativeStudy for the determination of the reference values of the enzymes aspartate aminnotransferase (AST), alanine aminotransferase (ALT) and gama- glutamyl transferase (GGT), in sérumpt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.conferencePlaceLisboa, Portugalpt_PT
oaire.citation.endPage48pt_PT
oaire.citation.issue31pt_PT
oaire.citation.startPage44pt_PT
oaire.citation.titleBoletim Epidemiológico Observaçõespt_PT
oaire.citation.volume11pt_PT
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT