- Allergy: Evaluation of 16 years (2007–2022) results of the shared external quality assessment program in Belgium, Finland, Portugal and The NetherlandsPublication . Heron, Michiel; Schreurs, Marco W.J.; Haagen, Inez-Anne; China, Bernard; Faria, Ana Paula; Vanhanen, Anna-Riitta; Thelen, Marc; Weykamp, Cas W.Objectives: This paper evaluates 16 year results of the Allergy EQA program shared by EQA organisers in Belgium, Finland, Portugal, and The Netherlands. Methods: The performance of Thermo Fisher and Siemens user groups (in terms of concordance between both groups, between laboratory CV, prevalence of clinically significant errors) and suitability of samples (stability and validity of dilution of patient samples) are evaluated using data of 192 samples in the EQA programs from 2007 to 2022. Measurands covered are total IgE, screens and mixes, specific IgE extracts and allergen components. Results: There is perfect (53 %), acceptable (40 %) and poor (6 %) concordance between both method groups. In case of poor concordance the best fit with clinical data is seen for Thermo Fisher (56 %) and Siemens (26 %) respectively. The between laboratory CV evolves from 7.8 to 6.6 % (Thermo Fisher) and 7.3 to 7.7 % (Siemens). The prevalence of blunders by individual laboratories is stable for Siemens (0.4 %) and drops from 0.4 to 0.2 % for Thermo Fisher users. For IgE, the between year CV of the mean of both user groups is 1 %, and a fifteen-fold dilution of a patient sample has an impact of 2 and 4 % on the recovery of Thermo Fisher and Siemens user groups. Conclusions: The analytical performance of Thermo Fisher is slightly better than that of Siemens users but the clinical impact of this difference is limited. Stability of the sample and the low impact of dilution on the recovery of measurands demonstrates the suitability for purpose of the EQA program.
- Portuguese EQA Assessment in Parasite Morphology 26 years experiencePublication . Correia, Helena; Júlio, Cláudia; Baptista-Fernandes, Teresa; Faria, Ana PaulaThe Parasite Morphology Programme was implemented in 1996 by the Portuguese External Quality Assessment Programme (PNAEQ), with a pilot round the previous year, which includes the assessment of stool and blood samples, as well as other matrices. The program is supported by a group of experts for sample selection and preparation, result analysis and training. Aim: Evaluation of the performance of participants in the parasite morphology program by optical microscopy (1996-2022).
- A importância da Avaliação Externa da Qualidade em Microbiologia do Ar (2010-2022)Publication . Cano, Manuela; Faria, Ana Paula; Correia, Helena; Rosa, Nuno; Almeida, Cristina; Júlio, CláudiaA legislação nacional veio impor regras de eficiência dos sistemas de climatização de edifícios que permitem melhorar o desempenho energético e garantir uma boa qualidade do ar interior, estabelecendo, entre outros, requisitos de qualidade do ar através da adoção de concentrações máximas de referência para poluentes químicos e microbiológicos (bactérias e fungos) e obrigando à realização de auditorias periódicas à qualidade de ar interior (QAI) em edifícios. Face ao aumento significativo das auditorias à QAI surgiu a necessidade de harmonizar procedimentos de amostragem/análise e encontrar soluções para a obtenção de resultados comparáveis. A Unidade de Ar e Saúde Ocupacional (UASO) implementou os procedimentos necessários à acreditação dos ensaios de acordo com o referencial da norma ISO/IEC 17025, indicador inequívoco de competência técnica. Face à inexistência de programas de avaliação externa da qualidade (AEQ), a UASO, em colaboração com o Programa Nacional de Avaliação Externa da Qualidade (PNAEQ), organizou em 2010 o programa piloto de AEQ – Microbiologia do Ar- contagem de bactérias e fungos, e em 2012 o programa de Microbiologia do Ar – Identificação de fungos, que se mantêm atualmente em funcionamento. Objetivo: Harmonização dos procedimentos e avaliação do desempenho dos Laboratórios no Programa Nacional de Avaliação externa da Qualidade em Microbiologia do Ar, entre 2010 e 2022