Repository logo
 
Publication

Evaluation of the Indoor Air Quality in Restaurants Before and After a Smoking Ban in Portugal

dc.contributor.authorMadureira, Joana
dc.contributor.authorMendes, Ana
dc.contributor.authorSantos, Helder
dc.contributor.authorVilaça, Jorge
dc.contributor.authorNeves, Maria Paula
dc.contributor.authorMayan, Olga
dc.contributor.authorTeixeira, João Paulo
dc.date.accessioned2012-01-24T17:10:59Z
dc.date.available2012-01-24T17:10:59Z
dc.date.issued2011-07-26
dc.description.abstractOn 14th August 2007, Portugal instituted a smoking ban in most indoor public places. The goal of this work was to quantify the effects of this ban on indoor air quality (IAQ) in Portuguese restaurants. Ten restaurants were investigated before and after the ban and the following indoor parameters measured: respirable suspended particulate matter (RSP), total volatile organic compounds (TVOC), benzene (C6H6), carbon monoxide (CO), carbon dioxide (CO2), temperature and relative humidity. Results show a statistically significant decrease in RSP and CO concentrations after the ban, as well as for TVOC and benzene concentrations. Additionally, the monitored CO2 concentrations widely exceeded 1800 mg·m-3 (reference for acceptable ventilation rates), suggesting inefficient ventilation of the indoor spaces. This paper provides the first comparison of IAQ in Portugal before and after the introduction of smoke-free law and these results confirm the positive impact of the law in the indoor air that became smoke-free after the legislation. This information should be provided to decision makers as it has significant health implications. This law thus appear to achieve the aim of protecting people from exposure to unwanted pollutants resulting from poor IAQ.por
dc.identifier.citationMadureira J, Mendes A, Santos H, Vilaça J, Neves MP, Mayan O, Teixeira JP. Evaluation of the Indoor Air Quality in Restaurants Before and After a Smoking Ban in Portugal. Indoor and Built Environment, July 26, 2011, DOI: 10.1177/1420326X11409459por
dc.identifier.issn1420-326X
dc.identifier.otherESSN: 1423-0070
dc.identifier.urihttp://hdl.handle.net/10400.18/404
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherSAGEpor
dc.relation.publisherversionhttp://ibe.sagepub.com/content/early/2011/07/19/1420326X11409459por
dc.subjectBenzenepor
dc.subjectIndoor air qualitypor
dc.subjectSmoking banpor
dc.subjectRespirable particulate matterpor
dc.subjectRestaurantspor
dc.subjectTobacco smoke pollutionpor
dc.subjectAr e Saúde Ocupacionalpor
dc.titleEvaluation of the Indoor Air Quality in Restaurants Before and After a Smoking Ban in Portugalpor
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage9por
oaire.citation.startPage1por
oaire.citation.titleIndoor and Built Environmentpor
rcaap.rightsrestrictedAccesspor
rcaap.typearticlepor

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
2011 Fumo tabaco restaurantes.pdf
Size:
147.34 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: