Environment and Health in Children Day Care Centres (ENVIRH) - Study rationale and protocol

dc.contributor.authorAraújo-Martins, J.
dc.contributor.authorCarreiro Martins, P.
dc.contributor.authorViegas, J.
dc.contributor.authorAelenei, D.
dc.contributor.authorCano, M.M.
dc.contributor.authorTeixeira, João Paulo
dc.contributor.authorPaixão, P.
dc.contributor.authorPapoila, A.L.
dc.contributor.authorLeiria-Pinto, P.
dc.contributor.authorPedro, C.
dc.contributor.authorRosado-Pinto, J.
dc.contributor.authorAnnesi-Maesano, I.
dc.contributor.authorNeuparth, N.
dc.date.accessioned2015-02-03T15:44:38Z
dc.date.available2015-02-03T15:44:38Z
dc.date.issued2014-11
dc.descriptionProjeto financiado pela Fundação para a Ciência e Tecnologiapor
dc.description.abstract[PT] Antecedentes: A qualidade do ar interior (IAQ) é considerada um determinante importante da saúde humana. A associação entre a exposição a compostos orgânicos voláteis, partículas, ácaros, bolores e bactérias em creches (DCC) não é perfeitamente clara. O objectivo deste estudo foi estudar esses efeitos. Metodologia - desenho do estudo: Este estudo decorreu em duas Fases. A Fase I incluiu uma avaliação de 45 DCCs (25 em Lisboa e 20 no Porto, visando 5.161 crianças). Nesta Fase, foram avaliadas as características dos edifícios, o CO2 e a temperatura ambiente/humidade relativa no interior. Também foi distribuído um questionário de saúde respiratória das crianças derivado do ISAAC (Estudo Internacional sobre a Asma e Alergias em Crianças). A Fase II englobou duas avaliações e incluiu 20 DCCs seleccionadas da fase I, após uma análise de clusters (11 em Lisboa e 9 no Porto, visando 2.287 crianças). Nesta Fase, foram recolhidos dados sobre a ventilação, IAQ (qualidade do ar interior), parâmetros de conforto térmico, saúde em termos respiratórios e alérgicos, marcadores biológicos de inflamação das vias respiratórias, padrões de infecção de vírus respiratórios e stress dos pais e crianças. Discussão: Este documento destaca a metodologia que pode ser implementada por outros investigadores que realizam estudos sobre a associação entre a saúde respiratória e a qualidade do ar interior, em creches e infantários. J. Araújo-Martins, P. Carreiro Martins, J. Viegas, D. Aelenei, M.M. Cano, J.P. Teixeira, P. Paixão, A.L. Papoila, P. Leiria-Pinto, C. Pedro, J. Rosado-Pinto, I. Annesi-Maesano, N. Neuparthpor
dc.description.abstract[ENG] Background: Indoor air quality (IAQ) is considered an important determinant of human health. The association between exposure to volatile organic compounds, particulate matter, house dust mite, molds and bacteria in day care centers (DCC) is not completely clear. The aim of this project was to study these effects. Methods - study design: This study comprised two phases. Phase I included an evaluation of 45 DCCs (25 from Lisbon and 20 from Oporto, targeting 5161 children). In this phase, building characteristics, indoor CO2 and air temperature/relative humidity, were assessed. A children's respiratory health questionnaire derived from the ISAAC (International Study on Asthma and Allergies in Children) was also distributed. Phase II encompassed two evaluations and included 20 DCCs selected from phase I after a cluster analysis (11 from Lisbon and 9 from Oporto, targeting 2287 children). In this phase, data on ventilation, IAQ, thermal comfort parameters, respiratory and allergic health, airway inflammation biomarkers, respiratory virus infection patterns and parental and child stress were collected. Results: In Phase I, building characteristics, occupant behavior and ventilation surrogates were collected from all DCCs. The response rate of the questionnaire was 61.7% (3186 children). Phase II included 1221 children. Association results between DCC characteristics, IAQ and health outcomes will be provided in order to support recommendations on IAQ and children's health. A building ventilation model will also be developed. Discussion: This paper outlines methods that might be implemented by other investigators conducting studies on the association between respiratory health and indoor air quality at DCC. J. Araújo-Martins, P. Carreiro Martins, J. Viegas, D. Aelenei, M.M. Cano, J.P. Teixeira, P. Paixão, A.L. Papoila, P. Leiria-Pinto, C. Pedro, J. Rosado-Pinto, I. Annesi-Maesano, N. Neuparthpor
dc.description.sponsorshipThe activities of project ENVIRH were funded by research grants from national funds attributed by Fundação para a Ciência e Tecnologia (Project references -PTDC/SAUESA/100275/2008 and PEST-OE/MAT/UI0006/2011).por
dc.identifier.citationRev Port Pneumol. 2014 Nov-Dec;20(6):311-23. doi: 10.1016/j.rppneu.2014.02.006. Epub 2014 Apr 18.por
dc.identifier.doi10.1016/j.rppneu.2014.02.006
dc.identifier.issn0873-2159
dc.identifier.urihttp://hdl.handle.net/10400.18/2759
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherElsevier España/ Sociedade Portuguesa de Pneumologiapor
dc.relation.publisherversionhttp://www.elsevier.pt/en/revistas/revista-portuguesa-pneumologia-320/artigo/environment-and-health-in-children-day-care-centres-90368882por
dc.subjectChildren Day Care Centrespor
dc.subjectIndoor Air Qualitypor
dc.subjectRespiratory Diseasepor
dc.subjectAirway Inflamationpor
dc.subjectBuilding Ventilationpor
dc.subjectEnvironmental Exposurepor
dc.subjectAr e Saúde Ocupacionalpor
dc.subjectInflamação das Vias Respiratórias;por
dc.subjectVentilação de Edifíciospor
dc.subjectCrechespor
dc.subjectExposição Ambientalpor
dc.subjectQualidade do Ar Interiorpor
dc.subjectDoença Respiratóriapor
dc.titleEnvironment and Health in Children Day Care Centres (ENVIRH) - Study rationale and protocolpor
dc.title.alternativeAmbiente e Saúde em Creches e Infantários (ENVIRH)- FundamentaÇão e protocolo do estudopor
dc.typejournal article
dspace.entity.typePublication
oaire.awardURIinfo:eu-repo/grantAgreement/FCT/3599-PPCDT/PTDC%2FSAU-ESA%2F100275%2F2008/PT
oaire.citation.endPage323por
oaire.citation.startPage311por
oaire.citation.titleRevista Portuguesa de Pneumologiapor
oaire.citation.volume20(6)por
oaire.fundingStream3599-PPCDT
project.funder.identifierhttp://doi.org/10.13039/501100001871
project.funder.nameFundação para a Ciência e a Tecnologia
rcaap.rightsembargoedAccesspor
rcaap.typearticlepor
relation.isProjectOfPublication5ffceb17-2386-487a-a9ad-1f3363444c19
relation.isProjectOfPublication.latestForDiscovery5ffceb17-2386-487a-a9ad-1f3363444c19

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
2014 revPortPulmonology.pdf
Size:
1010.79 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: