Repository logo
 
Publication

Criterios de extracción de muestra en situaciones especiales del cribado neonatal Revisión

dc.contributor.authorVila Vidal, María Magdalena
dc.contributor.authorLópez Galera, Rosa María
dc.contributor.authorGonzález Irazabal, Yolanda
dc.contributor.authorDelgado Pecellín, Carmen
dc.contributor.authorRausell Félix, Dolores
dc.contributor.authorCastiñeiras Ramos, Daisy
dc.contributor.authorEgea Mellado, José María
dc.contributor.authorRocha, Hugo
dc.contributor.authorYahyaoui Macías, Raquel
dc.contributor.authorRodríguez, Teresa
dc.contributor.authorEscribano Hernández, Vanesa
dc.contributor.authorRodríguez Fraga, Olaia
dc.contributor.authorBóveda Fontán, Dolores
dc.contributor.authorMarín Soria, José Luis
dc.contributor.authorComisión de Diagnóstico Perinatal de la Sociedad Española de Medicina del Laboratorio
dc.date.accessioned2020-05-03T20:13:59Z
dc.date.available2020-05-03T20:13:59Z
dc.date.issued2019-03-04
dc.description.abstractLa espectrometría de masas en tándem (MS-MS) ha permitido ampliar el alcance del cribado neonatal. Eso hace más complicado determinar el momento más adecuado para la toma de muestra, sobre todo en recién nacidos prematuros y/o bajo peso y/o ingresados en unidades neonatales. El objetivo del presente estudio ha sido revisar las normas de toma de muestra de los distintos programas en estas situaciones, a nivel nacional e internacional. Se obtienen los datos a través de páginas web de salud pública, de plataformas de búsqueda o por contacto con los centros. Existe gran disparidad de criterios para la toma de una nueva muestra, incluso dentro de un mismo país. La limitación de información disponible, hizo imposible obtener resultados de muchos países, en particular de África, Asia o Latinoamérica. A pesar de que cada vez más estados se acogen a las recomendaciones del Clinical and Laboratory Standards Institute u otros organismos internacionales, el aumento del coste que implica, hace muy difícil conseguir la estandarización.pt_PT
dc.description.abstractThe most significant breakthrough in the newborn screening (NBS) programs was the introduction of the tandem mass spectrometry (MS-MS) to the laboratory, which makes it possible to detect multiple disorders. However, it is difficult to choose the ideal time for the specimen collection, particularly in preterm, low birth weight, and sick newborns. The aim of this study was to revise the protocols, in national and international programs for specimen collection in these newborns. Data were collected from web pages of public health, internet searches, and contact with the laboratories. The results showed a great disparity in criteria for a new specimen collection, as well as among different centres within a country. It has been difficult to obtain this information from many countries in Africa, Asia, and Latin America. Although an increasing number of laboratories follow the recommendations of the Clinical and Laboratory Standards Institute or other international guidelines, the increased cost involved makes standardisation difficult.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationRev Lab Clín. 2019;12(4):189-195. doi:10.1016/j.labcli.2019.01.006. Epub 2019 mar 4. Reviewpt_PT
dc.identifier.doi10.1016/j.labcli.2019.01.006pt_PT
dc.identifier.issn1888-4008
dc.identifier.urihttp://hdl.handle.net/10400.18/6592
dc.language.isospapt_PT
dc.language.isoeng
dc.peerreviewedyespt_PT
dc.publisherElsevierpt_PT
dc.relation.publisherversionhttps://www.elsevier.es/es-revista-revista-del-laboratorio-clinico-282-avance-resumen-criterios-extraccion-muestra-situaciones-especiales-S1888400819300273pt_PT
dc.subjectCribado Neonatalpt_PT
dc.subjectPrematuropt_PT
dc.subjectBajo Pesopt_PT
dc.subjectExtracción Muestrapt_PT
dc.subjectNewborn Screeningpt_PT
dc.subjectPretermpt_PT
dc.subjectLow Birth Weightpt_PT
dc.subjectSpecimen Collectionpt_PT
dc.subjectDoenças Genéticaspt_PT
dc.titleCriterios de extracción de muestra en situaciones especiales del cribado neonatal Revisiónpt_PT
dc.title.alternativeCriteria for specimen collection in special situations of Newborn Screening. Reviewpt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage195pt_PT
oaire.citation.issue4pt_PT
oaire.citation.startPage189pt_PT
oaire.citation.titleRevista del Laboratorio Clínicopt_PT
oaire.citation.volume12pt_PT
rcaap.embargofctDe acordo com política editorial da revista.pt_PT
rcaap.rightsembargoedAccesspt_PT
rcaap.typearticlept_PT

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1-s2.0-S1888400819300273-main.pdf
Size:
254.46 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: