Indoor Air Quality in Portuguese Archives: A Snapshot on Exposure Levels

dc.contributor.authorPinheiro, Catarina
dc.contributor.authorViegas, Carla
dc.contributor.authorViegas, Susana
dc.contributor.authorVeríssimo, Cristina
dc.contributor.authorBrandão, João
dc.contributor.authorMacedo, M Filomena
dc.date.accessioned2012-10-25T16:43:56Z
dc.date.available2012-10-25T16:43:56Z
dc.date.issued2012
dc.description.abstractIndoor air quality recently entered legislation in Portugal. Several parameters must be evaluated and kept within limits in order to obtain a certification for air quality and energy consumption. Certification parameters were analyzed in two Portuguese archives in order to assess indoor air quality both for people attending or working on these premises and for maintenance of a written heritage that must be retained for future generations. Carbon monoxide(CO) and carbon dioxide (CO2), formaldehyde, and fungal counts were kept within stipulated limits. Relative humidity (RH), volatile organic compounds (VOC), particulate matter (PM10), and ozone (O3) showed values above legislated levels and justified the implementation of corrective measures. In terms of conservation, studies on the limit values are still needed, but according to the available international guidelines, some of the analyzed parameters such as PM10, O3, and RH were also above desirable values. Corrective measures were proposed to these institutions. Although this study was only of a short duration, it proved valuable in assessing potential eventual problems and constitutes the first Portuguese indoor air quality assessment taking into consideration both aspects of an archive such as human health and heritage safekeeping.por
dc.identifier.citationJournal of Toxicology and Environmental Health, Part A: Current Issues 2012;75(22-23):1359-1370por
dc.identifier.issn0098-4108
dc.identifier.otherdoi: 10.1080/15287394.2012.721168
dc.identifier.urihttp://hdl.handle.net/10400.18/1091
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherTaylor & Francispor
dc.relation.publisherversionhttp://www.tandfonline.com/doi/abs/10.1080/15287394.2012.721168por
dc.subjectAir Quality Fungipor
dc.subjectInfecções Sistémicas e Zoonosespor
dc.titleIndoor Air Quality in Portuguese Archives: A Snapshot on Exposure Levelspor
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage1370por
oaire.citation.startPage1359por
oaire.citation.volume75por
rcaap.rightsrestrictedAccesspor
rcaap.typearticlepor

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Pinheiro_2012.pdf
Size:
504.76 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: