Browsing by Author "Vanhanen, Anna-Riitta"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- Allergy: Evaluation of 16 years (2007–2022) results of the shared external quality assessment program in Belgium, Finland, Portugal and The NetherlandsPublication . Heron, Michiel; Schreurs, Marco W.J.; Haagen, Inez-Anne; China, Bernard; Faria, Ana Paula; Vanhanen, Anna-Riitta; Thelen, Marc; Weykamp, Cas W.Objectives: This paper evaluates 16 year results of the Allergy EQA program shared by EQA organisers in Belgium, Finland, Portugal, and The Netherlands. Methods: The performance of Thermo Fisher and Siemens user groups (in terms of concordance between both groups, between laboratory CV, prevalence of clinically significant errors) and suitability of samples (stability and validity of dilution of patient samples) are evaluated using data of 192 samples in the EQA programs from 2007 to 2022. Measurands covered are total IgE, screens and mixes, specific IgE extracts and allergen components. Results: There is perfect (53 %), acceptable (40 %) and poor (6 %) concordance between both method groups. In case of poor concordance the best fit with clinical data is seen for Thermo Fisher (56 %) and Siemens (26 %) respectively. The between laboratory CV evolves from 7.8 to 6.6 % (Thermo Fisher) and 7.3 to 7.7 % (Siemens). The prevalence of blunders by individual laboratories is stable for Siemens (0.4 %) and drops from 0.4 to 0.2 % for Thermo Fisher users. For IgE, the between year CV of the mean of both user groups is 1 %, and a fifteen-fold dilution of a patient sample has an impact of 2 and 4 % on the recovery of Thermo Fisher and Siemens user groups. Conclusions: The analytical performance of Thermo Fisher is slightly better than that of Siemens users but the clinical impact of this difference is limited. Stability of the sample and the low impact of dilution on the recovery of measurands demonstrates the suitability for purpose of the EQA program.
- Avaliação Externa da Qualidade nos Point of Care Test (POCT)Publication . Faria, Ana Paula; Nunes, Baltazar; Correia, Helena; Brito, Cristina; Wahlstedt, Juha; Pakkanen, Anja; Vanhanen, Anna-Riitta; Pelanti, Jonna; Rauvo, Päivi; Myllys, Raija; Eklund, Satu; Häkkinen, Teija; Nordberg, Ulla-Riitta; Cardoso, AnaO Programa Nacional de Avaliação Externa da Qualidade (PNAEQ), inserido no Departamento de Epidemiologia do Instituto Nacional de Saúde Doutor Ricardo Jorge (INSA, IP), Portugal, tem como objetivo promover, organizar e coordenar programas de Avaliação Externa da Qualidade Laboratorial (AEQ). Neste sentido, o PNAEQ estabeleceu um protocolo de colaboração com a entidade finlandesa Labquality de modo a alargar a oferta de programas disponíveis, englobando, entre outras, a área dos Testes Point of Care (POCT). Os primeiros programas de AEQ-POCT distribuídos pelo PNAEQ, em colaboração da Labquality, tiveram início em 2010 com os ensaios para Teste de Gravidez, Química Clínica e Glicose. Atualmente, estão disponíveis 26 programas de AEQ-POCT que abrangem as áreas de Química Clínica, Hematologia e Microbiologia. Os POCT são testes de diagnóstico rápido realizados fora do ambiente laboratorial em pequenos analisadores portáteis. A sua utilização não requer formação especializada em técnicas de laboratório, pelo que podem ser realizados por quaisquer profissionais de saúde ou até mesmo pelos doentes. Têm como finalidade a triagem de utentes, o diagnóstico de situações agudas, a monitorização de fármacos ou o acompanhamento de doenças crónicas. Em comparação com o laboratório, apresentam como vantagens a facilidade de uso, a diversidade de testes disponíveis, não requerem preparação prévia de reagentes e necessitam de poucos procedimentos de manutenção (a maioria dos dispositivos é de uso único). Também a colheita de sangue é menos invasiva (punção capilar), o volume da amostra é reduzido, o tempo de transporte é eliminado ou diminuído e não requerem preparação prévia das amostras (sangue total). Tudo isto, permite que o tempo de resposta seja imediato.
